17
o In addition, when the control panel detects an ambient
temperature greater than 95°C it shuts off all the elements. A
heating element that is shut off by the thermal protection can
only be turned back on when the ambient temperature drops
below 95°C.
Recall function
o The recall function enables settings to be recovered quickly when
the control has been switched off by the mains switch by
mistake.
o When the control has been switched off, you have 6 seconds to
switch it back on again. The execution of this function is only
available if at least one cooking zone was active and is confirmed
with an acoustic signal.
o If the appliance is switched back on within 6 seconds, it will
recall the power level of all cooking zones and the minutes and
seconds of all programmed timers.
Fan control (integrated cooling of the generator)
o The cooling of the hob is integrated within the plastic housing of
the inductor heat element. The operation of the fan is controlled
by the temperature which is measured at the heat sink.
o The fan switches on when a certain temperature is reached and
switches to a higher speed when the second temperature limit is
reached.
o The lower speed will begin at 45°C and the higher speed will
begin at 55°C.