Baumatic BHG300SS Bedienungsanleitung Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
20
GENERAL INJECTORS TABLE
Power (in watts) Kind of gas Nozzle
mm/100
Burners
Max. Min.
Natural 115
72
Rapid
Auxiliary
3000
1000
750
300
L.P.G.
Butane
Propane
85
50
Rapid
Auxiliary
3000
1000
900
370
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o IMPORTANT: The minimum flow adjustment process must
be completed before the appliance is next used.
Minimum flow adjustment for hob gas taps.
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o Switch the burner on
and set the knob at the
minimum position.
o Remove the knob from
the tap and place a
small bladed
screwdriver in the
centre of the tap shaft.
o Unscrew the adjusting
screw, in order to
increase the gas flow or
tighten the adjusting screw to decrease the gas flow.
o The correct adjustment is obtained when the flame has a
length of about 3 – 4 mm.
o For butane/propane gas, the adjusting screw must be tightly
screwed in.
o Refit the control knob.
Seitenansicht 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 26 27 28

Kommentare zu diesen Handbüchern

Keine Kommentare