
2
For future reference please record the following information which can be
found on the Rating Plate and the date of purchase which can be found in the
invoice:
Model Number .
Serial Number .
Date of Purchase .
TECHNICAL DATA
ELECTRICAL DETAILS
Rated Voltage: 230V ac 50Hz
Supply Connection: Switched Double-pole Isolator with 3mm contact separation
POWER INPUTS AND PROTECTION RATING
Model Max Total Min Fuse
kW Amps Protection Rating
B65 6.0 26.1 30A
BE2SS 3.5 15.2 16A
BVC2SS 2.9 12.6 16A
Mains Supply Connection Cable: 3 x 2.5mm2 Type H05 RR-F <HAR> marked
NOTE:
For cable connection details, see diagram on appliance base plate.
11
Once the electrical cable has been located into the correct terminals ensure that the brass links are in
place and that all screws in the terminal block are secured by tightening each screw to create the link
Kommentare zu diesen Handbüchern